GE F650-G-N-A-B-F-2-G-1-HI-C-E – Feeder Protection Relay

GE F650-G-N-A-B-F-2-G-1-HI-C-E – Feeder Protection Relay

Product Code: F650-G-N-A-B-F-2-G-1-HI-C-E
Availability: In Stock
Viewed 177 times

The GE F650-G-N-A-B-F-2-G-1-HI-C-E is an advanced feeder protection relay from the GE Multilin F650 series, designed for medium and high-voltage distribution systems. It provides comprehensive protection, control, metering, and automation for utility and industrial power networks. 

·Manager: Jinny

·E-mail:sales1@xrjdcs.com

·Tel: + 86-15359273791 (WhatsApp)

·Wechat: + 86-15359273791

Product Description

GE F650-G-N-A-B-F-2-G-1-HI-C-E – Feeder Protection Relay

Product Summary

The GE F650-G-N-A-B-F-2-G-1-HI-C-E is an advanced feeder protection relay from the GE Multilin F650 series, designed for medium and high-voltage distribution systems. It provides comprehensive protection, control, metering, and automation for utility and industrial power networks. This model supports configurable I/O, multiple communication protocols, and built-in sequence-of-events recording, making it suitable for modern smart-grid and substation automation environments.

Unlike traditional electromechanical protection relays, the F650 series integrates advanced logic, programmable settings, and IEC 61850 support, enhancing grid reliability and operational visibility.


Features & Functional Highlights

  • Feeder protection with overcurrent, thermal, under/overvoltage, frequency, and breaker failure functions

  • High-speed trip response and secure fault isolation for utility feeders

  • IEC 61850, Modbus, DNP3, and other communication protocols for SCADA integration

  • Large front LCD for local metering, event logs, and configuration navigation

  • Built-in waveform capture and disturbance recorder

  • Cyber-secure settings management with password and role-based access

  • Programmable logic for automation (PLC-style ladder logic)

  • Redundant power supply options for high availability

  • Conformal-coated PCB for harsh substation environment protection



Parameters 

CategorySpecification
Protection Types50/51, 50N/51N, 27, 59, 81O/U, 46, 49, 50BF, etc.
Nominal Control Voltage110–250 V AC/DC (model-dependent)
Current Inputs1 A or 5 A CT selectable
Digital I/OConfigurable dry-contact inputs & outputs
Communication PortsRS-485, Ethernet, USB, Fiber (G-version supports IEC 61850)
Time Stamp Accuracy≤1 ms with IRIG-B GPS synchronization
Operating Temperature−40°C to +70°C
Display40-character multi-line LCD
MountingDraw-out chassis, panel-mount
Relay Form Factor19-inch rack or cut-out flush mount

Structure & Internal Architecture

  1. Front HMI Panel – LCD display, keypad, LED indicators for status and alarms

  2. Main CPU & Protection DSP – Manages logic and real-time protective algorithms

  3. CT / VT Measurement Stage – Accepts analog feeder current & voltage inputs

  4. Output Trip Relays – Fast mechanical or solid-state trip contacts

  5. Communication Module – Ethernet + serial ports for SCADA/DCS connectivity

  6. Field-Replaceable Draw-Out Chassis – Enables relay replacement without rewiring

  7. Dual Power Supply (Optional) – Redundant 24 V DC / 125 V DC support



Typical Applications

  • Utility distribution feeders (primary & secondary substations)

  • Industrial MV switchgear and motor control centers

  • Renewable energy interconnection protection (solar, wind farm feeders)

  • Ring and radial feeder protection in smart grid networks

  • Backup or secondary protection for transformer and busbar systems

  • IEC 61850 substation automation & GOOSE-based interlocking


Installation & Commissioning Guidelines

  • Install relay in a grounded control panel using the standard 19-inch rack cutout

  • Connect CT/VT wiring according to ANSI / IEC terminal labels

  • Use GE EnerVista software for configuration, diagnostics, settings upload/download

  • Perform primary injection test before energizing feeder

  • Validate time synchronization if using SCADA event correlation

  • Record baseline oscillography data for future maintenance benchmark

    F650-G-N-A-B-F-2-G-1-HI-C-E


Maintenance & Lifecycle Support

  • Relay self-diagnostics available via front panel or Ethernet

  • Cybersecurity firmware updates supplied by GE Digital Energy portal

  • No calibration required—only periodic functional trip testing

  • Event logs and SOE records can be exported via USB or Ethernet

  • Hot-swappable draw-out chassis allows replacement without shutdown

  • Recommended spare inventory: 1 relay per 15–20 feeders in a station


Additional Notes

  • The long configuration code (G-N-A-B-F-2-G-1-HI-C-E) specifies hardware, protocols, I/O count, and power options

  • Fully compliant with IEC 61850 Ed.2, IEEE C37.90, and NERC PRC cyber standards

  • Supports remote engineering access for digital substations

Write a review

Note: HTML is not translated!
    Bad           Good

The GE F650-G-N-A-B-F-2-G-1-HI-C-E is an advanced feeder protection relay from the GE Multilin F650 series, designed for medium and high-voltage distribution systems. It provides comprehensive protection, control, metering, and automation for utility and industrial power networks. 

·Manager: Jinny

·E-mail:sales1@xrjdcs.com

·Tel: + 86-15359273791 (WhatsApp)

·Wechat: + 86-15359273791