GE IC697PWR748 power module
Product Definition: The GE IC697PWR748 is a rack-mounted power supply module manufactured by General Electric (GE), specifically designed for the GE Fanuc 90-70 Series PLC (Programmable Logic Controller) systems.
Ship to you via Fedex/DHL/TNT/UPS/EMS 丨 Package: Original packing with cartons 丨 Shipping Port: Xiamen
·Manager: Jinny
·E-mail:sales1@xrjdcs.com
·Tel: + 86-15359273791 (WhatsApp)
·Wechat: + 86-15359273791
Product Description
GE IC697PWR748
1. Overview
- Product Definition: The GE IC697PWR748 is a rack-mounted power supply module manufactured by General Electric (GE), specifically designed for the GE Fanuc 90-70 Series PLC (Programmable Logic Controller) systems.
- Core Function: Provides stable and reliable power to CPU modules, I/O modules, and other expansion modules in the PLC system, ensuring continuous system operation.
- Design Features: Features high power density, redundant power supply capability, and multiple protection mechanisms, making it suitable for industrial automation environments.
2. Specifications
- Model: IC697PWR748
- Power Output: Total power of 90W, with three output channels: +5V DC (max. 18A), +12V DC (max. 1.5A), and -12V DC (max. 1A)
- Input Voltage: 48V DC (nominal), with a range of 35-60V DC
- Physical Dimensions: Standard rack-mount size (refer to the specific manual for details)
- Operating Environment: Temperature: -20°C to +85°C (storage), -10°C to +60°C (operation); Humidity: 5-95% non-condensing
- Protection Functions: Electronic overcurrent protection, short-circuit protection, and overvoltage protection (5V output voltage limited to 6.7V)
- Certifications: CE, UL, cUL, etc. (compliant with industrial safety standards)
- Compatibility: Compatible with GE 90-70 Series PLC racks, supporting dual-rack power supply
3. Product Features
- Dual-Rack Power Supply Capability: Can supply power to two independent racks simultaneously, enhancing system expandability.
- High Efficiency and Reliability:
- 90W full-load output to meet the needs of high-density modules.
- Electronic overcurrent limiting automatically reduces the output voltage to protect the module.
- Easy Installation:
- Slide-in rack design, enabling quick installation via a 48-pin backplane connector.
- Equipped with mounting screws to ensure secure fixation.
- Safety Protection:
- Built-in fuse (5A, 250V, 5x20mm) to prevent the spread of internal faults.
- Short-circuit protection to avoid damage caused by overload.
- Status Monitoring: Power status LED indicators provide real-time feedback on operating status and fault information.
4. Structure and Composition
- Hardware Structure:
- Main Module: Includes power conversion circuit, protection circuit, and LED indicators.
- Connectors: A 48-pin backplane interface on the left (for insertion into the rack) for power and signal transmission.
- Heat Dissipation Design: Natural heat dissipation (no fan) via heat conduction through the metal housing.
- Mounting Accessories: Mounting screws are provided with the module, suitable for standard DIN rail or rack mounting.
5. Application Fields
- Industrial Automation: Production line control, robotic systems, and smart manufacturing equipment.
- Process Control: Process automation and monitoring in the chemical, petroleum, and power industries.
- Infrastructure: PLC power supply for data centers and traffic control systems.
- Robotics Technology: Provides stable power support for automated machinery.
- Others: Any industrial scenarios requiring high reliability and redundant power supply support.
6. Installation and Maintenance
Installation Steps
- Power-off Operation: Turn off the rack power to ensure safety.
- Module Insertion: Align with the 48-pin backplane connector on the left of the rack, insert the module, and secure it with screws.
- Power Connection: Confirm the input voltage is within the 35-60V DC range, then connect the power supply.
Dual-Rack Configuration (if required)
- Use a pre-wired cable (e.g., IC697CBL700) to connect the second rack.
- Ensure the total load does not exceed 90W, and the second rack only consumes 5V power (<5.2A).
Power-on Test: Check the LED status (a lit power indicator indicates normal operation).
Maintenance Points
- Regular Inspection:
- Verify that the wiring is secure, with no looseness or corrosion.
- Monitor the ambient temperature to avoid exceeding the operating range.
- Clean dust from the module surface to ensure good heat dissipation.
- Troubleshooting:
- If the LED is abnormal (e.g., off or flashing), turn off the power and check the input power or fuse.
- When replacing the fuse, use the specified specification (5A, 250V).
- Redundancy Design Recommendation: In critical applications, configure dual power supply modules for redundant backup to improve system fault tolerance.
————————————————————————————————————————————————————————————————————————
Original factory direct supply, quality assurance - GE module professional supplier
Consult now to obtain the latest technical information and quotation for GE modules!
·Manager: Jinny ·E-mail: sales1@xrjdcs.com
·Tel: + 86-15359273791(WhatsApp) ·Wechat: + 86-15359273791
————————————————————————————————————————————————————————————————————————
Product Definition: The GE IC697PWR748 is a rack-mounted power supply module manufactured by General Electric (GE), specifically designed for the GE Fanuc 90-70 Series PLC (Programmable Logic Controller) systems.
Ship to you via Fedex/DHL/TNT/UPS/EMS 丨 Package: Original packing with cartons 丨 Shipping Port: Xiamen
·Manager: Jinny
·E-mail:sales1@xrjdcs.com
·Tel: + 86-15359273791 (WhatsApp)
·Wechat: + 86-15359273791