GE SR750-P5-G5-S5-HI-A20-R-T — Feeder Protection Relay (SR Series 750)
The GE SR750-P5-G5-S5-HI-A20-R-T is a programmable microprocessor-based feeder protection relay from GE’s SR 750 Series. It is designed to protect medium-voltage and low-voltage feeders in utility, industrial, and commercial power distribution systems.
·Manager: Jinny
·E-mail:sales1@xrjdcs.com
·Tel: + 86-15359273791 (WhatsApp)
·Wechat: + 86-15359273791
Product Description
GE SR750-P5-G5-S5-HI-A20-R-T — Feeder Protection Relay (SR Series 750)
Quick Description
The GE SR750-P5-G5-S5-HI-A20-R-T is a programmable microprocessor-based feeder protection relay from GE’s SR 750 Series. It is designed to protect medium-voltage and low-voltage feeders in utility, industrial, and commercial power distribution systems.
This relay provides advanced protection, metering, event recording, automation logic, and multi-protocol communication, making it suitable for both new substations and retrofit applications.
The GE SR750-P5-G5-S5-HI-A20-R-T is a programmable microprocessor-based feeder protection relay from GE’s SR 750 Series. It is designed to protect medium-voltage and low-voltage feeders in utility, industrial, and commercial power distribution systems.
This relay provides advanced protection, metering, event recording, automation logic, and multi-protocol communication, making it suitable for both new substations and retrofit applications.
Key Functions & Protection Elements
-
Phase & ground overcurrent protection (50/51, 50N/51N)
-
Thermal overload protection (49)
-
Breaker failure protection (50BF)
-
Under/overfrequency & voltage protection (81, 27, 59)
-
Demand, energy, and power factor metering
-
Trip / close coil supervision & breaker health diagnostics
-
Programmable logic (FlexLogic™) for custom automation
-
Sequence-of-events, waveform disturbance recorder, and fault logging
.jpg)
-
Phase & ground overcurrent protection (50/51, 50N/51N)
-
Thermal overload protection (49)
-
Breaker failure protection (50BF)
-
Under/overfrequency & voltage protection (81, 27, 59)
-
Demand, energy, and power factor metering
-
Trip / close coil supervision & breaker health diagnostics
-
Programmable logic (FlexLogic™) for custom automation
-
Sequence-of-events, waveform disturbance recorder, and fault logging
.jpg)
Hardware / Option Code Meaning
Code Section Meaning P5 5 Amp CT input rating G5 Communication option (Ethernet + RS-485 multiprotocol) S5 Standard I/O package with programmable outputs HI HMI with front panel display & keypad A20 20 records oscillography memory depth R Conformal coated board (harsh-environment protection) T Harsh temperature rating (ext. industrial range)
| Code Section | Meaning |
|---|---|
| P5 | 5 Amp CT input rating |
| G5 | Communication option (Ethernet + RS-485 multiprotocol) |
| S5 | Standard I/O package with programmable outputs |
| HI | HMI with front panel display & keypad |
| A20 | 20 records oscillography memory depth |
| R | Conformal coated board (harsh-environment protection) |
| T | Harsh temperature rating (ext. industrial range) |
Technical Parameters
-
Nominal Current Inputs: 1 A or 5 A selectable
-
Control Power: 48–250 V DC / 100–240 V AC
-
Operating Temperature Range: −40 °C to +70 °C (T-rated)
-
Front Display: 40-character multi-line LCD with status LEDs
-
Memory & Recording: 20 oscillography event files, 1024 SOE time-stamped events
-
Accuracy: IEC 60255 class metering & protection grade
-
Communications: Ethernet TCP/IP, Modbus, DNP3, IEC 61850 (G5 option), RS-485 serial
-
Mounting Style: Draw-out chassis, 19-inch rack or panel cut-out
-
Trip Outputs: Form-C relay contacts, user programmable
-
Cybersecurity: Password lockout + role-based access (firmware dependent)
-
Nominal Current Inputs: 1 A or 5 A selectable
-
Control Power: 48–250 V DC / 100–240 V AC
-
Operating Temperature Range: −40 °C to +70 °C (T-rated)
-
Front Display: 40-character multi-line LCD with status LEDs
-
Memory & Recording: 20 oscillography event files, 1024 SOE time-stamped events
-
Accuracy: IEC 60255 class metering & protection grade
-
Communications: Ethernet TCP/IP, Modbus, DNP3, IEC 61850 (G5 option), RS-485 serial
-
Mounting Style: Draw-out chassis, 19-inch rack or panel cut-out
-
Trip Outputs: Form-C relay contacts, user programmable
-
Cybersecurity: Password lockout + role-based access (firmware dependent)
Internal Architecture
-
Protection DSP – Executes real-time relay algorithms
-
Metering Stage – True RMS measurement for energy & demand values
-
High-speed Trip Outputs – Mechanical relays rated for breaker coils
-
Event / waveform memory – Non-volatile flash for fault forensics
-
Communication Processor – Manages SCADA, IEC 61850, gateway protocols
-
HMI Panel – Local configuration, alarm acknowledgment, breaker controls
.jpg)
-
Protection DSP – Executes real-time relay algorithms
-
Metering Stage – True RMS measurement for energy & demand values
-
High-speed Trip Outputs – Mechanical relays rated for breaker coils
-
Event / waveform memory – Non-volatile flash for fault forensics
-
Communication Processor – Manages SCADA, IEC 61850, gateway protocols
-
HMI Panel – Local configuration, alarm acknowledgment, breaker controls
.jpg)
Application Scenarios
-
Primary/secondary distribution feeders (3-phase, 50/60 Hz)
-
Industrial switchgear / MCC feeder protection
-
Ring and radial feeder automation in utilities
-
Renewable energy collector circuits (wind, solar, hydro)
-
Smart-grid SCADA and substation automation
-
Retrofit of legacy electromechanical relays (same form factor cutout)
-
Primary/secondary distribution feeders (3-phase, 50/60 Hz)
-
Industrial switchgear / MCC feeder protection
-
Ring and radial feeder automation in utilities
-
Renewable energy collector circuits (wind, solar, hydro)
-
Smart-grid SCADA and substation automation
-
Retrofit of legacy electromechanical relays (same form factor cutout)
Installation & Commissioning Notes
-
Install in draw-out cradle to allow relay replacement without rewiring
-
CT polarity and grounding must follow ANSI or IEC wiring diagrams
-
Recommended to perform primary injection testing before energizing feeder
-
Time sync may be via IRIG-B, SNTP, or SCADA (depending on comms option)
-
Configure and upload settings using EnerVista SR configuration software
-
Install in draw-out cradle to allow relay replacement without rewiring
-
CT polarity and grounding must follow ANSI or IEC wiring diagrams
-
Recommended to perform primary injection testing before energizing feeder
-
Time sync may be via IRIG-B, SNTP, or SCADA (depending on comms option)
-
Configure and upload settings using EnerVista SR configuration software
Maintenance & Lifecycle Support
-
Relay is self-monitoring; front panel shows “Relay OK / Relay Fail” alarm
-
Trip contacts rated for 30,000+ mechanical operations
-
Event logs and oscillography can be exported via USB or Ethernet
-
Firmware upgradable using GE EnerVista Toolsuite
-
Suggested spare inventory: 1 relay for every 10–12 feeders in a station
-
Relay is self-monitoring; front panel shows “Relay OK / Relay Fail” alarm
-
Trip contacts rated for 30,000+ mechanical operations
-
Event logs and oscillography can be exported via USB or Ethernet
-
Firmware upgradable using GE EnerVista Toolsuite
-
Suggested spare inventory: 1 relay for every 10–12 feeders in a station
Additional Notes
-
The SR750 series is part of the same family as SR469, SR489, SR759, etc.
-
UL, CE, CSA, and IEEE C37.90 certified for protection systems
-
Still supported by GE Grid Solutions with firmware/security updates
-
The SR750 series is part of the same family as SR469, SR489, SR759, etc.
-
UL, CE, CSA, and IEEE C37.90 certified for protection systems
-
Still supported by GE Grid Solutions with firmware/security updates