GE IS220PDOAH1B Discrete Output Module

GE IS220PDOAH1B Discrete Output Module

Product Code: IS220PDOAH1B
Availability: In Stock
Viewed 229 times

The GE IS220PDOAH1B is one of the core components of the Mark VIe system and part of the GE Speedtronic gas turbine control system.

Ship to you via Fedex/DHL/TNT/UPS/EMS   Package: Original packing with cartons   Shipping Port: Xiamen   

·Manager: Jinny

·E-mail:sales1@xrjdcs.com

·Tel: + 86-15359273791 (WhatsApp)

·Wechat: + 86-15359273791

Product Description

GE IS220PDOAH1B

I. Overview

The GE IS220PDOAH1B is one of the core components of the Mark VIe system and part of the GE Speedtronic gas turbine control system. It is widely used in power generation, process control, and industrial automation fields. Its main function is to control actuators such as relays and solenoid valves through digital output signals, achieving precise control of industrial equipment.

II. Parameters

Basic Parameters

  • Model: IS220PDOAH1B
  • Manufacturer: General Electric
  • Series: Mark VIe
  • Product Type: Discrete Output Pack
  • Number of Channels: 12 relay output channels (some documents mention 24 channels, which needs further verification)
  • Input Voltage: 24V DC (maximum 28.6V DC)
  • Input Current: 15A (some documents mention 10A, to be confirmed)
  • Operating Temperature Range: -30°C to +65°C (ambient temperature)
  • Insulation Class: IP20 (standard protection level)

Physical Specifications

  • Dimensions: 8.26 cm (height) × 4.19 cm (width) × 12.1 cm (depth)
  • Weight: Approximately 0.8 kg
  • Ethernet Interface: Dual RJ45 connectors (10BaseT/100BaseTX)
  • Power Input: 3-pin power interface (28V DC input)
  • Output Interface: DC-37 pin connector, compatible with various terminal boards

GE IS220PDOAH1B

III. Product Features

High Reliability and Safety

  • Adopts advanced control technology, supporting the selection of electromagnetic relays and solid-state relays to adapt to different load requirements.
  • Complies with the IEC 61508 standard, suitable for hazardous areas (Class 1, Zone 1).
  • Built-in soft-start and fast current-limiting functions to prevent faults caused by power fluctuations.

Flexible Communication and Diagnostics

  • Supports multiple communication protocols (such as ModbusProfibus-DP) and enables high-speed data exchange via Ethernet.
  • Equipped with LED status indicators and an infrared port for convenient local monitoring and fault troubleshooting.

Modular Design

  • Composed of a processor board and an acquisition board, supporting hot-swap installation for easy maintenance.
  • Can be seamlessly integrated with other modules of the Mark VIe system (such as input modules and power modules).

IV. Structure and Composition

Core Components

  • Processor Board: Shared among all Mark VIe distributed I/O modules, responsible for data processing and logic control.
  • Acquisition Board: Specifically designed for discrete outputs, directly connecting to the terminal board and controlling relays.

Connection Methods

  • Input End: Connected to the control network via dual RJ45 Ethernet interfaces, powered by a 3-pin power interface.
  • Output End: Docked with the terminal board through a DC-37 pin connector, supporting 12 relay outputs.

V. Application Fields

Industrial Automation

  • Widely used in gas turbine control and process automation in industries such as power plants, petroleum refining, and water treatment.
  • Supports integration with PLC and DCS systems to achieve complex logic control.

Safety and Redundancy Control

  • In hazardous areas (such as chemical plants), it is used in conjunction with the Mark VIeS safety system to meet TMR (Triple Modular Redundancy) requirements.

Energy Efficiency

  • High-efficiency design (>95%) reduces energy consumption, suitable for motor drive and energy-saving renovation projects.

VI. Installation and Maintenance

Installation Steps

  • Install the module on a DIN rail or a dedicated base to ensure electrical isolation and mechanical fixation.
  • Physically connect to the terminal board via the DC-37 connector, and wiring must comply with the 24V DC standard.

Maintenance and Diagnostics

  • Use LED indicators to monitor the module status in real-time (such as power supply and output activation signals).
  • Perform local configuration and fault troubleshooting through the infrared port, supporting remote diagnostics.
  • Regularly check the relay contacts and connector contact conditions to avoid faults caused by oxidation or loosening.

————————————————————————————————————————————————————————————————————————

Xingruijia

Original factory direct supply, quality assurance - GE module professional supplier

Consult now to obtain the latest technical information and quotation for GE modules!

·Manager: Jinny                                         ·E-mail: sales1@xrjdcs.com     

·Tel: + 86-15359273791(WhatsApp)   ·Wechat: + 86-15359273791

————————————————————————————————————————————————————————————————————————

Write a review

Note: HTML is not translated!
    Bad           Good

The GE IS220PDOAH1B is one of the core components of the Mark VIe system and part of the GE Speedtronic gas turbine control system.

Ship to you via Fedex/DHL/TNT/UPS/EMS   Package: Original packing with cartons   Shipping Port: Xiamen   

·Manager: Jinny

·E-mail:sales1@xrjdcs.com

·Tel: + 86-15359273791 (WhatsApp)

·Wechat: + 86-15359273791